The flow is visible at a glance.
This is a current galvanometer that checks the flow of fluid by observing the movement of a ball (or float) inside a transparent tube.
The flow rate cannot be confirmed.
With protective cover
The metal protective cover reduces the possibility of damage from external impacts.
The mounting direction does not matter.
Because it uses a spring inside, you can freely adjust the mounting position to upward, downward, or sideways.
This is a current galvanometer that checks the flow of fluid by observing the movement of a ball (or float) inside a transparent tube.
The flow rate cannot be confirmed.
With protective cover
The metal protective cover reduces the possibility of damage from external impacts.
The mounting direction does not matter.
Because it uses a spring inside, you can freely adjust the mounting position to upward, downward, or sideways.
MKC type download (1322KB) |
Model List
Model | Dimensions (mm)[Due to the casting surface, there may be individual variations in dimensions.] | Standard flow rate (L/min) | ||||
Connection port diameter | Length | Width | Depth | Minimum | maximum | |
MKC20-1TA | Rc1/8 | 80 | 30 | 22 | 30 | 150 |
MKC20-2TA | Rc1/4 | 80 | 30 | 22 | 30 | 150 |
MKC20-3TA | Rc3/8 | 86 | 30 | 22 | 30 | 150 |
MKC30-2TA | Rc1/4 | 100 | 44 | 32 | 60 | 300 |
MKC30-3TA | Rc3/8 | 104 | 44 | 32 | 60 | 300 |
MKC30-4TA | Rc1/2 | 110 | 44 | 32 | 60 | 300 |
MKC35-4TA | Rc1/2 | 124 | 49 | 44 | 100 | 1000 |
MKC35-6TA | Rc3/4 | 124 | 49 | 44 | 100 | 1000 |
MKC45-6TA | Rc3/4 | 142 | 62 | 50 | 200 | 1000 |
MKC45-8TA | Rc1 | 142 | 62 | 50 | 200 | 1000 |
*Supplementary information regarding the model number
When the connection inlet and outlet are R-shaped male threads, the model number will be MKC□□-□TOA. Example: MKC20-3TOA
When the connection port is an R-type male thread, the model number will be MKC□□-□TOMA. Example: MKC20-3TOMA
When the connection outlet is an R-type male thread, the model number will be MKC□□-□TMOA. Example: MKC20-3TMOA
When the connection port is an R-type male thread, the model number will be MKC□□-□TOMA. Example: MKC20-3TOMA
When the connection outlet is an R-type male thread, the model number will be MKC□□-□TMOA. Example: MKC20-3TMOA
Standard specifications
Fluid | gas | ||
Connection | Rc female thread | Change to R male thread It can also be used in combination with an R-type male thread. | |
Eur-lex.europa.eu eur-lex.europa.eu | Maximum 80℃ | - | |
pressure resistance | 1MPa | - | |
Material | transparent tube | Acrylic | - |
Protective covers | BC (gun metal) | We can also manufacture them in aluminum. | |
Fitting | C3604 (brass) | We can also manufacture them in stainless steel (SUS). | |
Spring | SUS304 | - | |
Nylon ball | Nylon 66 | Cylindrical floats may also be used. | |
O-ring | Nitrile rubber | - | |