[Visualizing flow rates prevents equipment problems before they occur]
Because the water flow can be visually monitored, signs of insufficient flow or blockages can be detected early.
[Flow rate management and adjustment in a single unit]
Flow rate monitoring and adjustment are integrated into a single unit. This reduces the number of parts and contributes to space saving in piping.
[Increased design flexibility through flexible mounting positions]
Because it can be installed in any direction, it minimizes constraints during equipment design and modification.
PDF download (1153KB) |
When ordering or requesting a quote□Please specify your choice.
Model MKTV□□-□TW | Regular flow rate □L / min |
Example: MKTV25-2TW normal flow rate 3L/min
*For R-type male thread connections, the model number is MKTV25-□TOW. Example: MKTV25-3TOW
*For R-type male thread connections, the model number is MKTV25-□TOW. Example: MKTV25-3TOW
Fluid | Wed | ||
flow | See above | Please contact us if you require a flow rate below or above the standard specification. | |
Connection | Rc female thread | Change to R male thread It can also be used in combination with an R-type male thread. | |
Eur-lex.europa.eu eur-lex.europa.eu | Maximum 80℃ | - | |
pressure resistance | 1MPa | - | |
Material | transparent tube | Acrylic | - |
Fitting | C3604 (brass) | - | |
Spring | SUS304 | - | |
Nylon ball | Nylon 66 | Cylindrical floats may also be used. | |
Miniature bulb | BC | - | |
O-ring | Nitrile rubber | - | |