Move to the text

MKCM type OIL SIGNAL

A switch is with flow quantity
  I detect fluid flow and let it is ON, or a switch be off with flow quantity of the designation
  ※The switch is rigid (the set point change from a trace is not possible)
I can see a flow at first sight
  It is a rheoscope confirming fluid flow by the movement of transparent floats in the jurisdiction
With protective cover
  By a metal protective cover possibility of the damage by shocks from the outside
  I reduce it.
The installation direction does not matter
  The posture when I attach it as I use a spring inside
  I look up and look down and can perform sideways-facing freely.
 

List of models

Model 
 Dimensions (mm)
Flow quantity (L/min)
 Connection diameter
Full length 
Overall width 
Depth 
The smallest inside diameter
φmm
Designated range of the operation flow quantity
Maximum
MKCM20-1TL-OFF
 Rc1/8 
80
30
22
6.5
 0.005 (5cc) - 2
5
MKCM20-1TL-ON
MKCM20-2TL-OFF
Rc1/4
80
30
22
6.5
 0.005 (5cc) - 2
5
MKCM20-2TL-ON
MKCM20-3TL-OFF
Rc3/8
86
30
25
6.5
 0.005 (5cc) - 2
5
MKCM20-3TL-ON
MKCM30-2TL-OFF
Rc1/4
104
43
32
9.5
 0.05 (50cc) - 5
10
MKCM30-2TL-ON
MKCM30-3TL-OFF
Rc3/8
104
43
32
9.5
 0.05 (50cc) - 5
10
MKCM30-3TL-ON
MKCM30-4TL-OFF
Rc1/2
110
43
32
9.5
 0.05 (50cc) - 5
10
MKCM30-4TL-ON
MKCM35-4TL-OFF
Rc1/2
124
49
44
 13.5
1.0-10
25
MKCM35-4TL-ON
MKCM35-6TL-OFF
Rc3/4
124
49
44
 13.5
1.0-10
25
MKCM35-6TL-ON
MKCM45-6TL-OFF
Rc3/4
142
62
50
18.0
3.0-15
50
MKCM45-6TL-ON
MKCM45-8TL-OFF
Rc1
142
62
50
18.0
3.0-15
50
MKCM45-8TL-ON
In the case of an order, an estimatePlease appoint the inside of this.
 
Model
MKCM □* -TL-OFF(ON)
Kind of the oil
(or viscosity cSt of the oil)
 Operation flow quantity of the switch
L/min
An example: Operation flow quantity 1L/min of the kind ISOVG32 switch of the MKCM20-2TL-OFF oil
※The point of contact method, please appoint OFF method or ON method.
  When OFF method, fluid does not flow; the point of contact OFF (the normal opening A point of contact)
  When ON method, fluid does not flow; the point of contact ON (the normal closing B point of contact)
 

Standard specifications

Fluid
Oil 
Operation flow quantity
Please appoint it with the above, a flow quantity level in the designated range of the operation flow quantity.
(please appoint it with a flow quantity level less than 1/3 of the smallest use flow quantity if possible.)
Connection
Rc internal thread 
Change to R screw
The combination with the R screw is possible, too.
Heat-resistant temperature
A maximum of 60 degrees Celsius
I can produce the heat-resistant specifications (a maximum of 100 degrees Celsius), too. 
Withstand pressure
1MPa
I can produce the withstand pressure specifications (up to 5MPa), too.
The use of maximum voltage
DC, AC 300V  
Use of maximum electric current
DC, AC 0.5A  
Point of contact capacity
50VA  
Materials
Quality
Transparent pipe
Acrylic
The heat resistance, withstand pressure specifications product becomes brass pipe (C3604).
The heat resistance, withstand pressure specifications product cannot see the float.
Protective cover
BC (gunmetal)
I can produce the product made in aluminum, too.
Coupling
C3604 (brass)
I can produce the product made in SUS, too.
Spring
SUS304
-
Float with magnet
Aluminum
-
O ring
Nitrile rubber
Heat resistance, the withstand pressure specifications become the fluorine rubber.
Lead switch
Marketing product 
-
Lead
(authentic sample 200mm)
Marketing product 
Designation of the length of the lead,
The change to cab tire cord is possible, too.  

Flow switch precautions

1. Attention in the magnetic influence

  • Please use the lead switch for a switch acting with magnetism at the place that is not affected by the magnetic field.
  • When magnetic bodies such as the iron exist in the vicinity of the lead switch, it causes the malfunction.

2. Attention in the electrical connection

  • So that, as for the flow switch, an overcurrent does not flow in a lead switch for causes such as the ground connection defectiveness
    Please be careful about connection.
  • Please use the flow switch as a warning analyzer if possible.
    When you use it in conjunction with other electric apparatuses, please deal with influence when malfunction occurred after consideration enough.
  • When the use voltage, the use electric current hold it in check as small as possible and use it, the life of the lead switch gets longer.
    (usually possible use of approximately 1 million times of switch operation under the 100V0.5A situation)

3. Attention about the switch operation by a temperature change, the viscosity change of the oil

  • The operation flow quantity of a case and the switch which a switch does not operate with flow quantity of the setting when temperature, viscosity of the oil change
    I may change.
MAEDA KOKI
〒185-00140
4-15-3, Higashikoigakubo, Kokubunji-shi, Tokyo
TEL. 042-321-4831
FAX. 042-325-4298
Production sale of the appliance to flow control
Back to TOP