MKC type AIR SIGNAL
I can see a flow at first sight
It is a rheoscope confirming fluid flow by the movement of transparent balls (or a float) in the jurisdiction.
I cannot confirm the flow quantity.
With protective cover
By a metal protective cover, I reduce possibility of the damage by shocks from the outside.
The installation direction does not matter
Because I use a spring inside, the posture when I attach it looks up and looks down and can perform sideways-facing freely.
It is a rheoscope confirming fluid flow by the movement of transparent balls (or a float) in the jurisdiction.
I cannot confirm the flow quantity.
With protective cover
By a metal protective cover, I reduce possibility of the damage by shocks from the outside.
The installation direction does not matter
Because I use a spring inside, the posture when I attach it looks up and looks down and can perform sideways-facing freely.
List of models
Model
| Dimensions (mm)
| Standard specifications flow quantity
(L/min) | ||||
Connection diameter
| Full length
| Overall width
| Depth
| Minimum
| Maximum
| |
MKC20-1TA
| Rc1/8
| 80
| 30
| 22
| 30
| 150
|
MKC20-2TA
| Rc1/4
| 80
| 30
| 22
| 30
| 150
|
MKC20-3TA
| Rc3/8
| 86
| 30
| 22
| 30
| 150
|
MKC30-2TA
| Rc1/4
| 104
| 43
| 32
| 60
| 300
|
MKC30-3TA
| Rc3/8
| 104
| 43
| 32
| 60
| 300
|
MKC30-4TA
| Rc1/2
| 110
| 43
| 32
| 60
| 300
|
MKC35-4TA
| Rc1/2
| 124
| 50
| 44
| 100
| 1000
|
MKC35-6TA
| Rc3/4
| 124
| 50
| 44
| 100
| 1000
|
MKC45-6TA
| Rc3/4
| 142
| 62
| 50
| 200
| 1000
|
MKC45-8TA
| Rc1
| 142
| 62
| 50
| 200
| 1000
|
※Supplement about the model
The model in case of the R screw is MKC a connection entrance exit □* -□It becomes TOA. An example: MKC20-3TOA
The model in case of the R screw is MKC a connection entrance □* -□It becomes TOMA. An example: MKC20-3TOMA
The model in case of the R screw is MKC a connection exit □* -□It becomes TMOA. An example: MKC20-3TMOA
The model in case of the R screw is MKC a connection entrance □* -□It becomes TOMA. An example: MKC20-3TOMA
The model in case of the R screw is MKC a connection exit □* -□It becomes TMOA. An example: MKC20-3TMOA
Standard specifications
Fluid
| Gas
| ||
Connection
| Rc internal thread
| Change to R screw
The combination with the R screw is possible, too. | |
Heat-resistant temperature
| A maximum of 80 degrees Celsius
| -
| |
Withstand pressure
| 1MPa
| -
| |
Materials
| Transparent pipe
| Acrylic
| -
|
Protective cover
| BC (gunmetal)
| I can produce the product made in aluminum, too.
| |
Coupling
| C3604 (brass)
| I can produce the product made in SUS, too.
| |
Spring
| SUS304
| -
| |
Nylon ball
| Nylon 66
| I may use a cylindrical float.
| |
O ring
| Nitrile rubber
| -
|